Ventilation grill
Ref.
|
Protection degree
|
Dimensions in mm |
Cut-out in mm |
DR |
IP 44
|
Ø 24
|
Ø 18.5
|
DRG |
IP 44
|
Ø 54
|
Ø 30
|
DRG 1000/7035 |
IP 54
|
109 x 109
|
92 x 92
|
DRG 2000/7035 |
IP 54
|
145 x 145
|
125 x 125
|
DRG 3000/7035 |
IP 54
|
202 x 202
|
177 x 177
|
DRG 4000/7035 |
IP 54
|
252 x 252
|
223 x 223
|
DRG 6000/7035 |
IP 54
|
320 x 320
|
291 x 291
|
MOE/DRG1 |
Réalisation d’une découpe et installation d’une grille d’entrée ou de sortie d’air
|
||
MOE/DRG2 |
Réalisation de 2 découpes et installation d’une grille d’entrée et de sortie d’air
|
Material: self-extinguishable thermoplastic
Operating temperature: -15˚c to +70˚c
Colour: RAL 7035
Ref. Protection degree Dimensions in mm Cut-out in mm
Ventilators
Ref.
|
Free air flow(m3/h) |
Air flow with exhaust filter (m3/h) |
Power input (W)
|
Noise level (db)
|
Dimensions in mm |
Cut-out in mm |
DRGV1000/7035 |
29
|
18
|
12
|
33
|
109 x 109
|
92 x 92
|
DRGV2000/7035 |
64
|
46
|
19
|
44
|
145 x 145
|
125 x 125
|
DRGV3000/7035 |
110
|
64
|
20
|
40
|
202 x 202
|
177 x 177
|
DRGV4200/7035 |
160
|
113
|
18
|
40
|
252 x 252
|
223 x 223
|
DRGV4300/7035 |
265
|
207
|
40
|
42
|
252 x 252
|
223 x 223
|
DRGV6500/7035 |
505
|
380
|
65
|
54
|
320 x 320
|
291 x 291
|
DRGV6700/7035 |
725
|
580
|
150
|
66
|
320 x 320
|
291 x 291
|
MOE/DRGV1 |
Réalisation d’une découpe et installation d’un ventilateur à filtre
|
|||||
MOE/DRGV2 |
Réalisation de 2 découpes et installation d’un ventilateur à filtre et d’une grille de sortie d’air |
Material: self-extinguishable thermoplastic
Operating temperature: -15˚c to +70˚c
Colour: RAL 7035
Nominal Voltage: 230 V (DC fans also available)
Heating
Ref.
|
Heat output (Ta = 20°C)
|
Surface temperature
|
Air flow (m³/h)
|
Heating elements
|
RC10 |
10W
|
70°C
|
PTC
|
|
RC30 |
30W
|
100°C
|
PTC
|
|
RC60 |
60W
|
100°C
|
PTC
|
|
RC100 |
100W
|
100°C
|
PTC
|
|
RC150 |
150W
|
150°C
|
PTC
|
|
RC250 |
250W
|
70°C
|
35
|
Electrical resistance
|
RC400 |
400W
|
86°C
|
54
|
Electrical resistance
|
Nominal Voltage: 230V – 50/60Hz
Installation: DIN rail mountable
Operating temperature: -20°C to + 60°C
Thermostat (Th)
Installation: 35mm² DIN rail mountable / Protection degree: IP20 / Operating temperature: -20˚C to +40˚C
Ref.
|
Voltage (VAC) |
Unit of measure |
Type of contact |
Maximum voltage and intensity required |
|
Opening
|
Closing
|
||||
DGRT510 |
230
|
Bimetallic |
Switch in neutral position |
250VAC/10A resistive load |
250VAC/5A resistive load |
DRGT520 |
230
|
Opening
|
250VAC/10A resistive load |
||
DRGT530 |
230
|
Closing
|
250VAC/5A resistive load
|
Installation: 35mm² DIN rail mountable
Protection degree: IP20
Operating temperature: -20°C to +40°C
Ref.
|
Voltage (VAC) |
Unit of measure |
Type of contact |
Maximum voltage and intensity required |
|
Opening
|
Closing
|
||||
DRGH600 |
230
|
Opening
|
250VAC/5A resistive load |
Thermostats (Th)
Installation : encliquetable sur RAIL DIN de 35mm²
Indice de protection : IP 20
Température de fonctionnement : -20°C à +40°C
Ref. | Tension (VAC) |
Elément de mesure |
Type de contact |
Tension et intensité max commandée | |
Ouverture | Fermeture | ||||
DRGH600 | 230 | A ouverture | 250VAC/10A charge résistive |
/ |
Hygrostat (Hy)
Installation : encliquetable sur RAIL DIN de 35mm²
Indice de protection : IP 20
Température de fonctionnement : -20°C à +40°C
Air conditioning
1. Outdoor air conditioning / 2. Outdoor air con. / 3. Compact air con. / 4. Indoor air con.
Europoly offers a range of air conditioning and air circulation options. We, alongside the client, will calculate the most suitable and necessary thermal output. If however, you choose to use your own air conditioning device, we also offer to prepare and pre-assemble the equipment.
Isolation
Europoly offers an entire sandwich construction system:
Addition of polyurethane mousse
Problems with temperature and temperature variation inside enclosures are very common. These two issues can cause considerable constraints regarding electrical equipment.
The addition of polyurethane mousse between two layers of fibre-glass sheeting allows for:
– the slowing down of the increase in temperature inside the enclosure (temperature does not reach extreme heights until later in the day)
– the slowing down of the decrease in temperature inside the enclosure: (temperature does not reach extreme lows until later in the day, reduced need for heating elements)
– a reduction in the rate with which the temperature inside the enclosure decreases: (significant decrease in condensation)