{"id":5505,"date":"2026-10-28T17:34:03","date_gmt":"2026-10-28T16:34:03","guid":{"rendered":"https:\/\/europoly.com\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/"},"modified":"2026-10-29T16:21:31","modified_gmt":"2026-10-29T15:21:31","slug":"outdoor-polyester-meter-cupboard-how-to-choose-the-right-one","status":"publish","type":"post","link":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/","title":{"rendered":"Outdoor polyester meter cupboard: how to choose the right one"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">An outdoor meter cabinet houses the metering equipment for an electrical connection and protects it from the elements, impact and corrosion. For a power-monitored connection ranging from 37 to 250 kVA, it must remain accessible at all times to the network operator, who must be able to operate the individual main circuit breaker without the user\u2019s assistance, according to a<a target=\"_blank\" rel=\"noopener\" href=\"https:\/\/www.enedis.fr\/media\/2064\/download\"> technical note from Enedis.<\/a><\/p>\n\n<p class=\"wp-block-paragraph\">This article explains what a meter cabinet contains, what the network operator expects from the enclosure, how glass-fibre-reinforced polyester makes a difference, and how to select and draw up a set of specifications. It also shows how the cabinet and its cabling are designed to work together: Europoly manufactures polyester cabinets with a meter compartment, whilst <a href=\"https:\/\/polyelec.com\">Polyelec<\/a> carries out the electrical cabling.<\/p>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h2 class=\"wp-block-heading\">What is a meter cabinet used for?<\/h2>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading\">The role of the cupboard<\/h3>\n\n<p class=\"wp-block-paragraph\">A meter cabinet is an outer enclosure, mounted on a concrete plinth or foundation, which houses the metering and connection equipment for an electrical installation. It serves two purposes: to protect this equipment and to ensure that network technicians have permanent access to it.<\/p>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading\">Permanent or site-based meter cabinet<\/h3>\n\n<p class=\"wp-block-paragraph\">The term covers two distinct concepts. The top results for a search on \u2018metering cabinet\u2019 are construction equipment hire companies, which supply distribution and metering cabinets to provide a temporary power supply to a building site or event.<\/p>\n\n<p class=\"wp-block-paragraph\">This article discusses the permanent distribution board, which is installed for the lifetime of a connection. For temporary power supply to a building site, the article on single-phase or three-phase site distribution boards sets out the selection criteria.<\/p>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h2 class=\"wp-block-heading\">Yellow tariff, C4, monitored power: understanding the terms<\/h2>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading\">Monitored power connection<\/h3>\n\n<p class=\"wp-block-paragraph\">A power-monitored connection corresponds to a power rating of 37 to 250 kVA. According to <a target=\"_blank\" rel=\"noopener\" href=\"https:\/\/www.enedis.fr\/media\/2064\/download\">Enedis<\/a>, it comprises a connection to the grid, an individual main circuit breaker (CCPI) and an individual branch circuit. The connection to the grid is always three-phase with a neutral. It is rated in stages: 100 A for 37 to 60 kVA, 200 A for 60 to 120 kVA and 400 A for 120 to 250 kVA.<\/p>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading\">Yellow tariff and C4 segment<\/h3>\n\n<p class=\"wp-block-paragraph\">This particular power range is often referred to as the \u2018yellow tariff\u2019 or the \u2018C4 segment\u2019. The <a target=\"_blank\" rel=\"noopener\" href=\"https:\/\/opera-energie.com\/compteur-c4\/\">C4 segment refers<\/a> to businesses connected to the low-voltage network with a contracted power of between 36 and 250 kVA, fitted with an SME\/SMI-type meter. These terms primarily relate to billing. The distribution board, however, depends on the power rating of the connection and the requirements of the network operator.<\/p>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading\">What\u2019s in the meter box<\/h3>\n\n<p class=\"wp-block-paragraph\">The meter, modem, test sockets and, where applicable, other equipment are installed on the front panel of the control panel, in accordance with the <a target=\"_blank\" rel=\"noopener\" href=\"https:\/\/www.enedis.fr\/media\/2064\/download\">Enedis<\/a> guidelines. For new installations, the CCPI is integrated into a meter cabinet that complies with an Enedis specification for power-monitored connections.<\/p>\n\n<p class=\"wp-block-paragraph\">Alongside this enclosure, the cabinet often houses the control or distribution section of the equipment: protective devices, contactors and branch circuits. <a target=\"_blank\" rel=\"noopener\" href=\"https:\/\/www.groupe-cahors.com\/sites\/default\/files\/armoires.pdf\">A cabinet manufacturer\u2019s catalogue<\/a> also distinguishes between control panels in accordance with NF C 14100 and operating panels in accordance with NF C 17200. This internal wiring is <a target=\"_blank\" rel=\"noopener\" href=\"https:\/\/polyelec.com\/\">Polyelec\u2019s<\/a> speciality, and the company carries it out within the cabinet manufactured by Europoly.<\/p>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h2 class=\"wp-block-heading\">What the network operator expects from the budget<\/h2>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<p class=\"wp-block-paragraph\">The Enedis guidelines examined here relate to enclosures containing connection equipment, particularly those located on public land: charging points, kiosks and street lighting cabinets. The rules governing individual connections at property boundaries are set out in standard NF C 14100. These must be approved by the network operator for each project.<\/p>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading\">Approved equipment and responsibilities<\/h3>\n\n<p class=\"wp-block-paragraph\">For this equipment, the only connection components that may be used are those approved by Enedis. Enclosures are not generally subject to authorisation for use: their design, installation and maintenance are the responsibility of the equipment owner.<\/p>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading\">Access and manoeuvring<\/h3>\n\n<p class=\"wp-block-paragraph\">The same note sets out several rules regarding access:<\/p>\n\n<ol class=\"wp-block-list\">\n<li>the door of the meter box opens to 135 degrees;<\/li>\n\n\n\n<li>the clear space in front of the CCPI must be at least 80 cm, without encroaching on the carriageway;<\/li>\n\n\n\n<li>the base supporting the cable reel and the switch must be at least 40 cm above the finished floor level;<\/li>\n\n\n\n<li>a depth of 400 mm must be provided to accommodate the box, the meter and the metering devices;<\/li>\n\n\n\n<li>no equipment or pipework must be placed in front of the meter box;<\/li>\n\n\n\n<li>a panel covering the CCPI must open or be removed easily a<\/li>\n<\/ol>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading\">Protection ratings and Class II<\/h3>\n\n<p class=\"wp-block-paragraph\">For an additional meter integrated into public infrastructure, <a target=\"_blank\" rel=\"noopener\" href=\"https:\/\/www.enedis.fr\/media\/2065\/download\">Enedis<\/a> requires an enclosure with specifications equivalent to those of its own enclosures, namely IP 43 and IK 10.<\/p>\n\n<p class=\"wp-block-paragraph\">The connected panels are Class II. The heads of the fixing bolts are covered with insulating caps, which guarantee a dielectric strength of 4 kV for one minute at 50 Hz. Details of the IP and IK ratings can be found on the IP\/IK <a target=\"_blank\" rel=\"noopener\" href=\"https:\/\/europoly.com\/en\/protection-marking-ip-ik\/\">protection rating page.<\/a><\/p>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h2 class=\"wp-block-heading\">Why use polyester for an outdoor meter cabinet?<\/h2>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<p class=\"wp-block-paragraph\">A meter cabinet remains in place for years, exposed to rain, frost, sunlight and impacts. Glass-fibre-reinforced polyester meets these requirements in several respects.<\/p>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading\">Corrosion, insulation and finishing<\/h3>\n\n<ol class=\"wp-block-list\">\n<li>It does not rust. Its corrosion resistance minimises maintenance and the need for repainting.<\/li>\n\n\n\n<li>It is electrically insulating. The casing does not conduct electricity, which meets the Class II requirement for meter panels.<\/li>\n\n\n\n<li>Its surface can be treated. On Europoly cabinets, a surface gel coat improves resistance to chemical and atmospheric attack.<\/li>\n<\/ol>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading\">Heat, cold and condensation<\/h3>\n\n<p class=\"wp-block-paragraph\">When it comes to metering equipment, condensation is a key consideration. It occurs when the walls or internal components are colder than the dew point of the air inside, and can lead to corrosion and insulation faults. A high IP rating does not protect against it. The balance between watertightness and ventilation is discussed in the article <a target=\"_blank\" rel=\"noopener\" href=\"https:\/\/europoly.com\/en\/polyester-enclosure-ventilation-or-weatherproofing-for-your-outdoor-electrical-enclosure\/\">\u2018Polyester enclosures: ventilation or watertightness\u2019.<\/a><\/p>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading\">Integration into the environment<\/h3>\n\n<p class=\"wp-block-paragraph\">A meter cupboard is visible from the public area. A guidance <a target=\"_blank\" rel=\"noopener\" href=\"https:\/\/www.cote-dor.gouv.fr\/contenu\/telechargement\/5858\/71854\/file\/sdap_coffretsEDF.pdf\">note from a departmental architecture and heritage service<\/a> recommends that connection boxes be integrated into the architecture: they should be the same colour as neighbouring cladding and grouped together with other fittings on a fence.<\/p>\n\n<p class=\"wp-block-paragraph\">Other manufacturers offer <a target=\"_blank\" rel=\"noopener\" href=\"https:\/\/www.groupe-cahors.com\/sites\/default\/files\/armoires.pdf\">polyester switchboards<\/a> for loads up to 250 kVA, with IP55 and IK10 ratings, in RAL 1015 beige or painted in other RAL colours, for use in urban, suburban or rural areas, mounted on a plinth or concrete foundation. To compare enclosures and switchboards, see the page on<a target=\"_blank\" rel=\"noopener\" href=\"https:\/\/europoly.com\/en\/polyester-electrical-enclosures-advantages-limitations-and-applications-in-industrial-environments\/\"> industrial polyester electrical enclosures.<\/a><\/p>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h2 class=\"wp-block-heading\">Criteria for choosing an outdoor meter cabinet<\/h2>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading\">Power capacity and scalability<\/h3>\n\n<p class=\"wp-block-paragraph\">The current rating (100 A, 200 A or 400 A) determines the equipment to be housed. Enedis recommends allowing for future expansion of the recess, so that a 100 A meter can later be upgraded to a 200 A or 400 A meter without altering the installation. The 200 A and 400 A meter boxes have the same dimensions.<\/p>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading\">Internal dimensions<\/h3>\n\n<p class=\"wp-block-paragraph\">They must accommodate the meter box, which is 400 mm thick, with the door opening to 135 degrees, and provide sufficient working space. For example, the polyester cabinets in one manufacturer\u2019s catalogue are 1,250 mm high, 750 or 1,000 mm wide and 420 mm deep.<\/p>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading\">Fastening and lock<\/h3>\n\n<p class=\"wp-block-paragraph\">The lock must allow network technicians access at all times. The 11 mm triangular service key, referred to in the Enedis note for panels that conceal the CCPI, is the standard for this.<\/p>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading\">Installation instructions<\/h3>\n\n<p class=\"wp-block-paragraph\">These cabinets are installed on a plinth or a concrete foundation. To remove equipment without disconnecting the mains connection, Enedis recommends using a support bracket that can remain in place permanently.<\/p>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading\">Cabinet and cabling: considering both together<\/h3>\n\n<p class=\"wp-block-paragraph\">Considering the enclosure and the cabling together makes it possible to determine the dimensions, fixing points, cable entries and connection capacities right from the start. Europoly manufactures the <a target=\"_blank\" rel=\"noopener\" href=\"https:\/\/polyelec.com\/\">polyester<\/a> enclosure, whilst Polyelec carries out the internal electrical cabling and electrical integration. The connection and metering equipment remains that approved by the network operator.<\/p>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading\">Draw up the specifications<\/h3>\n\n<p class=\"wp-block-paragraph\">A detailed specification helps to avoid repeated correspondence with the network operator. It may include the following points:<\/p>\n\n<ol class=\"wp-block-list\">\n<li>the network operator and the applicable specification;<\/li>\n\n\n\n<li>the current rating: 100 A, 200 A or 400 A;<\/li>\n\n\n\n<li>the internal dimensions, including metering and access space;<\/li>\n\n\n\n<li>a door opening of 135 degrees and a clear space of 80 cm;<\/li>\n\n\n\n<li>the minimum height of 40 cm for the support plinth;<\/li>\n\n\n\n<li>the required IP and IK ratings;<\/li>\n\n\n\n<li>the locking system and operating key;<\/li>\n\n\n\n<li>the colour and appearance, as stipulated by town planning regulations;<\/li>\n\n\n\n<li>the installation method: plinth or concrete foundation;<\/li>\n\n\n\n<li>Internal electrical wiring: scope, diagram and labelling, to be carried out by <a href=\"https:\/\/polyelec.com\/\" target=\"_blank\" rel=\"noopener\">Polyelec<\/a> in conjunction with the switchboard.<\/li>\n<\/ol>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h2 class=\"wp-block-heading\">From counting to the finished product: Europoly, Gensollen and Polyelec<\/h2>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<p class=\"wp-block-paragraph\">A meter cabinet is sometimes part of a larger system, such as a street lighting cabinet or a plant room. The group\u2019s three companies cater for these requirements.<\/p>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading\">Europoly, the polyester membrane<\/h3>\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"noopener\" href=\"https:\/\/europoly.com\/en\/products\/\">Europoly<\/a> manufactures boxes, cabinets and enclosures made from glass-fibre-reinforced polyester.<\/p>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading\">Polyelec: cabling and electrical integration<\/h3>\n\n<p class=\"wp-block-paragraph\">Europoly manufactures the cabinet, whilst <a target=\"_blank\" rel=\"noopener\" href=\"https:\/\/polyelec.com\/\">Polyelec<\/a> carries out the cabling: internal electrical wiring and the integration of protective devices, contactors and branch circuits for the control or distribution section. The connection and metering equipment remains that approved by the network operator.<\/p>\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading\">Gensollen, the cabins and facilities<\/h3>\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"noopener\" href=\"https:\/\/gensollen.com\/\">Gensollen<\/a> designs bespoke industrial polyester enclosures and their fittings: HVAC ventilation, interior fittings and raised floors. This range meets requirements that go beyond a simple cabinet, such as a shelter or a plant room.<\/p>\n\n<div style=\"height:39px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div style=\"height:0px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h2 class=\"wp-block-heading\">Frequently Asked Questions<\/h2>\n\n<div style=\"height:39px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div class=\"schema-faq wp-block-yoast-faq-block\"><div class=\"schema-faq-section\" id=\"faq-question-1793202238520\"><strong class=\"schema-faq-question\">What is an outdoor meter cupboard used for?<\/strong> <p class=\"schema-faq-answer\">It houses the meter for an electricity connection, protects it from the elements, impact and corrosion, and remains accessible at all times to network technicians.<\/p> <\/div> <div class=\"schema-faq-section\" id=\"faq-question-1793202247543\"><strong class=\"schema-faq-question\">What do the \u2018yellow tariff\u2019 and \u2018C4 segment\u2019 refer to?<\/strong> <p class=\"schema-faq-answer\">According to Op\u00e9ra \u00c9nergie, these terms refer to the power range of 36 to 250 kVA in the lo<a href=\"https:\/\/opera-energie.com\/compteur-c4\/\" target=\"_blank\" rel=\"noopener\">w-voltage secto<\/a>r, fitted with a SME\/SMI meter. They relate primarily to billing, not to the design of the switchboard.<\/p> <\/div> <div class=\"schema-faq-section\" id=\"faq-question-1793202274148\"><strong class=\"schema-faq-question\">What IP and IK ratings are required for an outdoor meter cabinet?<\/strong> <p class=\"schema-faq-answer\">For an additional meter integrated into public infrastructure, <a href=\"https:\/\/www.enedis.fr\/media\/2065\/download\" target=\"_blank\" rel=\"noopener\">Enedis<\/a> requires specifications equivalent to those of its enclosures: IP 43 and IK 10. The requirements for a specific project must be confirmed with the network operator.<\/p> <\/div> <div class=\"schema-faq-section\" id=\"faq-question-1793202281200\"><strong class=\"schema-faq-question\">Who is responsible for the design and maintenance of the building envelope?<\/strong> <p class=\"schema-faq-answer\">With regard to public-sector infrastructure, <a href=\"https:\/\/www.enedis.fr\/media\/2064\/download\" target=\"_blank\" rel=\"noopener\">Enedis states<\/a> that the design, installation and maintenance of the building envelope are the responsibility of the infrastructure owner.<\/p> <\/div> <div class=\"schema-faq-section\" id=\"faq-question-1793202295236\"><strong class=\"schema-faq-question\">Why choose a polyester meter cabinet?<\/strong> <p class=\"schema-faq-answer\">Glass-fibre-reinforced polyester does not rust, is corrosion-resistant and does not conduct electricity. These characteristics mean that very little maintenance is required for a cladding that remains in place for years.<\/p> <\/div> <\/div>\n\n<div style=\"height:39px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h2 class=\"wp-block-heading\">Are you planning to build a meter cabinet?<\/h2>\n\n<div style=\"height:39px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<p class=\"wp-block-paragraph\">The Europoly teams will assess your requirements and find the right solution. <a target=\"_blank\" rel=\"noopener\" href=\"https:\/\/europoly.com\/en\/products\/\">Discover<\/a> the full Europoly range or <a target=\"_blank\" rel=\"noopener\" href=\"https:\/\/europoly.com\/en\/contact\/\">contact<\/a> an adviser. <a target=\"_blank\" rel=\"noopener\" href=\"https:\/\/polyelec.com\/\">Polyelec<\/a> carries out the cabling and electrical integration, whilst <a target=\"_blank\" rel=\"noopener\" href=\"https:\/\/gensollen.com\/\">Gensollen<\/a> manufactures the cabins and fits out the interiors.<\/p>\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>An outdoor meter cabinet houses the metering equipment for an electrical connection and protects it from the elements, impact and corrosion. For a power-monitored connection ranging from 37 to 250 kVA, it must remain accessible at all times to the network operator, who must be able to operate the individual main circuit breaker without the [&hellip;]<\/p>\n","protected":false},"author":241,"featured_media":5504,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_monsterinsights_skip_tracking":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[42],"tags":[],"class_list":["post-5505","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Outdoor polyester meter cabinet: criteria<\/title>\n<meta name=\"description\" content=\"Power-monitored connection, \u2018yellow\u2019 tariff, property boundary: the criteria for choosing an outdoor meter cabinet.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Outdoor polyester meter cabinet: criteria\" \/>\n<meta property=\"og:description\" content=\"Power-monitored connection, \u2018yellow\u2019 tariff, property boundary: the criteria for choosing an outdoor meter cabinet.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/\" \/>\n<meta property=\"og:site_name\" content=\"Europoly\" \/>\n<meta property=\"article:published_time\" content=\"2026-10-28T16:34:03+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-29T15:21:31+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/europoly.com\/wp-content\/uploads\/2026\/10\/Image-site-web-europoly-6.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"l.blivet@Europoly.com\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"l.blivet@Europoly.com\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"9 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/europoly.com\\\/en\\\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/europoly.com\\\/en\\\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\\\/\"},\"author\":{\"name\":\"l.blivet@Europoly.com\",\"@id\":\"https:\\\/\\\/europoly.com\\\/#\\\/schema\\\/person\\\/42905f23074bea1f430d4e30db0fd72d\"},\"headline\":\"Outdoor polyester meter cupboard: how to choose the right one\",\"datePublished\":\"2026-10-28T16:34:03+00:00\",\"dateModified\":\"2026-10-29T15:21:31+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/europoly.com\\\/en\\\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\\\/\"},\"wordCount\":1787,\"publisher\":{\"@id\":\"https:\\\/\\\/europoly.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/europoly.com\\\/en\\\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/europoly.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/Image-site-web-europoly-6.webp\",\"inLanguage\":\"en-US\"},{\"@type\":[\"WebPage\",\"FAQPage\"],\"@id\":\"https:\\\/\\\/europoly.com\\\/en\\\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\\\/\",\"url\":\"https:\\\/\\\/europoly.com\\\/en\\\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\\\/\",\"name\":\"Outdoor polyester meter cabinet: criteria\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/europoly.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/europoly.com\\\/en\\\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/europoly.com\\\/en\\\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/europoly.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/Image-site-web-europoly-6.webp\",\"datePublished\":\"2026-10-28T16:34:03+00:00\",\"dateModified\":\"2026-10-29T15:21:31+00:00\",\"description\":\"Power-monitored connection, \u2018yellow\u2019 tariff, property boundary: the criteria for choosing an outdoor meter cabinet.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/europoly.com\\\/en\\\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\\\/#breadcrumb\"},\"mainEntity\":[{\"@id\":\"https:\\\/\\\/europoly.com\\\/en\\\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\\\/#faq-question-1793202238520\"},{\"@id\":\"https:\\\/\\\/europoly.com\\\/en\\\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\\\/#faq-question-1793202247543\"},{\"@id\":\"https:\\\/\\\/europoly.com\\\/en\\\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\\\/#faq-question-1793202274148\"},{\"@id\":\"https:\\\/\\\/europoly.com\\\/en\\\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\\\/#faq-question-1793202281200\"},{\"@id\":\"https:\\\/\\\/europoly.com\\\/en\\\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\\\/#faq-question-1793202295236\"}],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/europoly.com\\\/en\\\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/europoly.com\\\/en\\\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\\\/#primaryimage\",\"url\":\"https:\\\/\\\/europoly.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/Image-site-web-europoly-6.webp\",\"contentUrl\":\"https:\\\/\\\/europoly.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/Image-site-web-europoly-6.webp\",\"width\":1920,\"height\":1080,\"caption\":\"Polyester cabinet with a metering compartment on the left and a pre-wired distribution compartment on the right.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/europoly.com\\\/en\\\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\\\/\\\/europoly.com\\\/en\\\/home\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Outdoor polyester meter cupboard: how to choose the right one\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/europoly.com\\\/#website\",\"url\":\"https:\\\/\\\/europoly.com\\\/\",\"name\":\"Europoly\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/europoly.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/europoly.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/europoly.com\\\/#organization\",\"name\":\"Europoly\",\"url\":\"https:\\\/\\\/europoly.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/europoly.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/europoly.com\\\/wp-content\\\/uploads\\\/2023\\\/10\\\/Logo-europoly-fabricants-armoires-polyester.png\",\"contentUrl\":\"https:\\\/\\\/europoly.com\\\/wp-content\\\/uploads\\\/2023\\\/10\\\/Logo-europoly-fabricants-armoires-polyester.png\",\"width\":283,\"height\":369,\"caption\":\"Europoly\"},\"image\":{\"@id\":\"https:\\\/\\\/europoly.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/europoly.com\\\/#\\\/schema\\\/person\\\/42905f23074bea1f430d4e30db0fd72d\",\"name\":\"l.blivet@Europoly.com\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0d741d63e74074402bdb3beaea7e449d20227b162ce4429e45823b1af084a881?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0d741d63e74074402bdb3beaea7e449d20227b162ce4429e45823b1af084a881?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0d741d63e74074402bdb3beaea7e449d20227b162ce4429e45823b1af084a881?s=96&d=mm&r=g\",\"caption\":\"l.blivet@Europoly.com\"},\"url\":\"https:\\\/\\\/europoly.com\\\/en\\\/author\\\/l-bliveteuropoly-com\\\/\"},{\"@type\":\"Question\",\"@id\":\"https:\\\/\\\/europoly.com\\\/en\\\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\\\/#faq-question-1793202238520\",\"position\":1,\"url\":\"https:\\\/\\\/europoly.com\\\/en\\\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\\\/#faq-question-1793202238520\",\"name\":\"What is an outdoor meter cupboard used for?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"It houses the meter for an electricity connection, protects it from the elements, impact and corrosion, and remains accessible at all times to network technicians.\",\"inLanguage\":\"en-US\"},\"inLanguage\":\"en-US\"},{\"@type\":\"Question\",\"@id\":\"https:\\\/\\\/europoly.com\\\/en\\\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\\\/#faq-question-1793202247543\",\"position\":2,\"url\":\"https:\\\/\\\/europoly.com\\\/en\\\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\\\/#faq-question-1793202247543\",\"name\":\"What do the \u2018yellow tariff\u2019 and \u2018C4 segment\u2019 refer to?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"According to Op\u00e9ra \u00c9nergie, these terms refer to the power range of 36 to 250 kVA in the lo<a href=\\\"https:\\\/\\\/opera-energie.com\\\/compteur-c4\\\/\\\" target=\\\"_blank\\\" rel=\\\"noopener\\\">w-voltage secto<\\\/a>r, fitted with a SME\\\/SMI meter. They relate primarily to billing, not to the design of the switchboard.\",\"inLanguage\":\"en-US\"},\"inLanguage\":\"en-US\"},{\"@type\":\"Question\",\"@id\":\"https:\\\/\\\/europoly.com\\\/en\\\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\\\/#faq-question-1793202274148\",\"position\":3,\"url\":\"https:\\\/\\\/europoly.com\\\/en\\\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\\\/#faq-question-1793202274148\",\"name\":\"What IP and IK ratings are required for an outdoor meter cabinet?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"For an additional meter integrated into public infrastructure, <a href=\\\"https:\\\/\\\/www.enedis.fr\\\/media\\\/2065\\\/download\\\" target=\\\"_blank\\\" rel=\\\"noopener\\\">Enedis<\\\/a> requires specifications equivalent to those of its enclosures: IP 43 and IK 10. The requirements for a specific project must be confirmed with the network operator.\",\"inLanguage\":\"en-US\"},\"inLanguage\":\"en-US\"},{\"@type\":\"Question\",\"@id\":\"https:\\\/\\\/europoly.com\\\/en\\\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\\\/#faq-question-1793202281200\",\"position\":4,\"url\":\"https:\\\/\\\/europoly.com\\\/en\\\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\\\/#faq-question-1793202281200\",\"name\":\"Who is responsible for the design and maintenance of the building envelope?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"With regard to public-sector infrastructure, <a href=\\\"https:\\\/\\\/www.enedis.fr\\\/media\\\/2064\\\/download\\\" target=\\\"_blank\\\" rel=\\\"noopener\\\">Enedis states<\\\/a> that the design, installation and maintenance of the building envelope are the responsibility of the infrastructure owner.\",\"inLanguage\":\"en-US\"},\"inLanguage\":\"en-US\"},{\"@type\":\"Question\",\"@id\":\"https:\\\/\\\/europoly.com\\\/en\\\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\\\/#faq-question-1793202295236\",\"position\":5,\"url\":\"https:\\\/\\\/europoly.com\\\/en\\\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\\\/#faq-question-1793202295236\",\"name\":\"Why choose a polyester meter cabinet?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Glass-fibre-reinforced polyester does not rust, is corrosion-resistant and does not conduct electricity. These characteristics mean that very little maintenance is required for a cladding that remains in place for years.\",\"inLanguage\":\"en-US\"},\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Outdoor polyester meter cabinet: criteria","description":"Power-monitored connection, \u2018yellow\u2019 tariff, property boundary: the criteria for choosing an outdoor meter cabinet.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/","og_locale":"en_US","og_type":"article","og_title":"Outdoor polyester meter cabinet: criteria","og_description":"Power-monitored connection, \u2018yellow\u2019 tariff, property boundary: the criteria for choosing an outdoor meter cabinet.","og_url":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/","og_site_name":"Europoly","article_published_time":"2026-10-28T16:34:03+00:00","article_modified_time":"2026-10-29T15:21:31+00:00","og_image":[{"width":1920,"height":1080,"url":"https:\/\/europoly.com\/wp-content\/uploads\/2026\/10\/Image-site-web-europoly-6.webp","type":"image\/webp"}],"author":"l.blivet@Europoly.com","twitter_card":"summary_large_image","twitter_misc":{"Written by":"l.blivet@Europoly.com","Est. reading time":"9 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/#article","isPartOf":{"@id":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/"},"author":{"name":"l.blivet@Europoly.com","@id":"https:\/\/europoly.com\/#\/schema\/person\/42905f23074bea1f430d4e30db0fd72d"},"headline":"Outdoor polyester meter cupboard: how to choose the right one","datePublished":"2026-10-28T16:34:03+00:00","dateModified":"2026-10-29T15:21:31+00:00","mainEntityOfPage":{"@id":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/"},"wordCount":1787,"publisher":{"@id":"https:\/\/europoly.com\/#organization"},"image":{"@id":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/#primaryimage"},"thumbnailUrl":"https:\/\/europoly.com\/wp-content\/uploads\/2026\/10\/Image-site-web-europoly-6.webp","inLanguage":"en-US"},{"@type":["WebPage","FAQPage"],"@id":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/","url":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/","name":"Outdoor polyester meter cabinet: criteria","isPartOf":{"@id":"https:\/\/europoly.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/#primaryimage"},"image":{"@id":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/#primaryimage"},"thumbnailUrl":"https:\/\/europoly.com\/wp-content\/uploads\/2026\/10\/Image-site-web-europoly-6.webp","datePublished":"2026-10-28T16:34:03+00:00","dateModified":"2026-10-29T15:21:31+00:00","description":"Power-monitored connection, \u2018yellow\u2019 tariff, property boundary: the criteria for choosing an outdoor meter cabinet.","breadcrumb":{"@id":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/#breadcrumb"},"mainEntity":[{"@id":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/#faq-question-1793202238520"},{"@id":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/#faq-question-1793202247543"},{"@id":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/#faq-question-1793202274148"},{"@id":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/#faq-question-1793202281200"},{"@id":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/#faq-question-1793202295236"}],"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/#primaryimage","url":"https:\/\/europoly.com\/wp-content\/uploads\/2026\/10\/Image-site-web-europoly-6.webp","contentUrl":"https:\/\/europoly.com\/wp-content\/uploads\/2026\/10\/Image-site-web-europoly-6.webp","width":1920,"height":1080,"caption":"Polyester cabinet with a metering compartment on the left and a pre-wired distribution compartment on the right."},{"@type":"BreadcrumbList","@id":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/europoly.com\/en\/home\/"},{"@type":"ListItem","position":2,"name":"Outdoor polyester meter cupboard: how to choose the right one"}]},{"@type":"WebSite","@id":"https:\/\/europoly.com\/#website","url":"https:\/\/europoly.com\/","name":"Europoly","description":"","publisher":{"@id":"https:\/\/europoly.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/europoly.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/europoly.com\/#organization","name":"Europoly","url":"https:\/\/europoly.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/europoly.com\/#\/schema\/logo\/image\/","url":"https:\/\/europoly.com\/wp-content\/uploads\/2023\/10\/Logo-europoly-fabricants-armoires-polyester.png","contentUrl":"https:\/\/europoly.com\/wp-content\/uploads\/2023\/10\/Logo-europoly-fabricants-armoires-polyester.png","width":283,"height":369,"caption":"Europoly"},"image":{"@id":"https:\/\/europoly.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/europoly.com\/#\/schema\/person\/42905f23074bea1f430d4e30db0fd72d","name":"l.blivet@Europoly.com","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/0d741d63e74074402bdb3beaea7e449d20227b162ce4429e45823b1af084a881?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/0d741d63e74074402bdb3beaea7e449d20227b162ce4429e45823b1af084a881?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/0d741d63e74074402bdb3beaea7e449d20227b162ce4429e45823b1af084a881?s=96&d=mm&r=g","caption":"l.blivet@Europoly.com"},"url":"https:\/\/europoly.com\/en\/author\/l-bliveteuropoly-com\/"},{"@type":"Question","@id":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/#faq-question-1793202238520","position":1,"url":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/#faq-question-1793202238520","name":"What is an outdoor meter cupboard used for?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"It houses the meter for an electricity connection, protects it from the elements, impact and corrosion, and remains accessible at all times to network technicians.","inLanguage":"en-US"},"inLanguage":"en-US"},{"@type":"Question","@id":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/#faq-question-1793202247543","position":2,"url":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/#faq-question-1793202247543","name":"What do the \u2018yellow tariff\u2019 and \u2018C4 segment\u2019 refer to?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"According to Op\u00e9ra \u00c9nergie, these terms refer to the power range of 36 to 250 kVA in the lo<a href=\"https:\/\/opera-energie.com\/compteur-c4\/\" target=\"_blank\" rel=\"noopener\">w-voltage secto<\/a>r, fitted with a SME\/SMI meter. They relate primarily to billing, not to the design of the switchboard.","inLanguage":"en-US"},"inLanguage":"en-US"},{"@type":"Question","@id":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/#faq-question-1793202274148","position":3,"url":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/#faq-question-1793202274148","name":"What IP and IK ratings are required for an outdoor meter cabinet?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"For an additional meter integrated into public infrastructure, <a href=\"https:\/\/www.enedis.fr\/media\/2065\/download\" target=\"_blank\" rel=\"noopener\">Enedis<\/a> requires specifications equivalent to those of its enclosures: IP 43 and IK 10. The requirements for a specific project must be confirmed with the network operator.","inLanguage":"en-US"},"inLanguage":"en-US"},{"@type":"Question","@id":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/#faq-question-1793202281200","position":4,"url":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/#faq-question-1793202281200","name":"Who is responsible for the design and maintenance of the building envelope?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"With regard to public-sector infrastructure, <a href=\"https:\/\/www.enedis.fr\/media\/2064\/download\" target=\"_blank\" rel=\"noopener\">Enedis states<\/a> that the design, installation and maintenance of the building envelope are the responsibility of the infrastructure owner.","inLanguage":"en-US"},"inLanguage":"en-US"},{"@type":"Question","@id":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/#faq-question-1793202295236","position":5,"url":"https:\/\/europoly.com\/en\/outdoor-polyester-meter-cupboard-how-to-choose-the-right-one\/#faq-question-1793202295236","name":"Why choose a polyester meter cabinet?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"Glass-fibre-reinforced polyester does not rust, is corrosion-resistant and does not conduct electricity. These characteristics mean that very little maintenance is required for a cladding that remains in place for years.","inLanguage":"en-US"},"inLanguage":"en-US"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/europoly.com\/wp-content\/uploads\/2026\/10\/Image-site-web-europoly-6.webp","_links":{"self":[{"href":"https:\/\/europoly.com\/en\/wp-json\/wp\/v2\/posts\/5505","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europoly.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/europoly.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/europoly.com\/en\/wp-json\/wp\/v2\/users\/241"}],"replies":[{"embeddable":true,"href":"https:\/\/europoly.com\/en\/wp-json\/wp\/v2\/comments?post=5505"}],"version-history":[{"count":5,"href":"https:\/\/europoly.com\/en\/wp-json\/wp\/v2\/posts\/5505\/revisions"}],"predecessor-version":[{"id":5514,"href":"https:\/\/europoly.com\/en\/wp-json\/wp\/v2\/posts\/5505\/revisions\/5514"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europoly.com\/en\/wp-json\/wp\/v2\/media\/5504"}],"wp:attachment":[{"href":"https:\/\/europoly.com\/en\/wp-json\/wp\/v2\/media?parent=5505"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/europoly.com\/en\/wp-json\/wp\/v2\/categories?post=5505"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/europoly.com\/en\/wp-json\/wp\/v2\/tags?post=5505"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}