A GRP cabinet is a glass reinforced polyester housing that protects electrical, electronic or measuring equipment outdoors as well as indoors, wherever conditions are harsh. It does not rust and does not conduct electricity. Its corrosion resistance makes it a solution for marine, industrial and urban environments, as Europoly explains.
This page presents all the Europoly cabinet ranges, from the modular cabinet to very large cabinets and cabins, the most common applications and the criteria to check before choosing. Enclosures have their own guide: the GRP enclosure guide.
Why choose a GRP cabinet
Corrosion and durability
Europoly reports excellent corrosion resistance for its polyester cabinets in environments classified C3 to C5 or CX under ISO 12944 part 2, notably because they cannot rust. By contrast, a metal cabinet has to rely on a paint system compliant with ISO 12944 and on stricter maintenance to keep its protection.
Insulation and impact resistance
Polyester is an insulator: the housing does not conduct electricity. Europoly manufactures IP65 and IK10 polyester cabinets in sandwich panels of polyester and polyurethane foam. The IK rating, defined by IEC 62262, measures resistance to mechanical impacts.
Electrical insulation and safety (Class II)
Polyester is naturally insulating.
Unlike metal cabinets, which always require earthing, a polyester cabinet can be designed with double insulation (Class II). This improves the safety of maintenance staff while simplifying some wiring diagrams.
It also avoids galvanic corrosion, which can occur when different metals are in contact in a damp environment.
Lower weight, logistics and total cost
For equivalent mechanical performance, a polyester cabinet is generally lighter than a steel or stainless steel solution.
This weight saving makes transport, handling and installation easier, especially on hard to reach sites, solar rooftops or complex technical infrastructure.
Over the whole life cycle of the installation, the absence of corrosion, fewer maintenance visits and the durability of the material generally optimise the total cost of ownership.
GRP enclosure or GRP cabinet: what are the differences?
An enclosure protects compact equipment: sensors, remote management modules, automation, small electrical distribution. It mounts on a wall, a pole or an existing structure. A cabinet houses more equipment and is used for electrical distribution, industrial automation, transport infrastructure and solar power plants.
The choice depends on the usable volume, the access needed for maintenance and how the installation is expected to evolve. Europoly enclosures, from the Micro Euro modular box to the Euro Instrum instrumentation enclosure, are presented in our GRP enclosure guide.
Comparison: GRP cabinet vs metal cabinets
| Criterion | Polyester cabinet | Painted or galvanised steel cabinet | Stainless steel cabinet |
|---|---|---|---|
| Corrosion resistance | Excellent | Depends on the coating | Good |
| Electrical insulation | Class II possible | Earthing mandatory | Earthing mandatory |
| Weight | Light | Medium | High |
| Maintenance | Very low | Regular | Low |
| Durability in aggressive environments | Very high | Variable | Good |
| Total cost over time | Optimised | Can rise quickly | Higher |
| Customisation | Very extensive | Medium | Limited |
In most corrosive environments or sites heavily exposed to the weather, a polyester cabinet today offers one of the best balances between safety, durability and total cost.
Europoly GRP cabinet ranges
Europoly manufactures five standard ranges of cabinets and cabins, from the modular cabinet to cabins more than 4 metres deep, and produces custom cabinets. All are made of glass reinforced polyester, insulating (class II) and rated for temperatures from minus 30 to plus 120 °C according to the product sheets.
| Range | Dimensions H x W x D (mm) | Protection | Key points |
|---|---|---|---|
| Euro Medium | 500 x 500 x 300 to 1,250 x 2,000 x 500 | IP55 or IP65, IK10 | Modular, more than 224 sizes |
| Maxi Euro 1500 | 1,500 high, modules 750 to 1,250 wide, 430 or 630 deep | IP65, IK10 | Modular assembly, integrated canopy |
| Maxi Euro 1900 | 1,800 x 600 x 430 to 1,900 x 5,325 x 1,000 | IP65, IK10 | Very large dimensions, heavy loads |
| Euro Urbain | 920 x 720 x 250 to 1,500 x 2,000 x 800 | IP44 or IP55, IK10 | Diamond points, anti graffiti |
| Mega Euro | 2,400 x 2,300 x 1,730 to 2,400 x 2,300 x 4,230 | IP55 or IP65, IK10 | Single or insulated double skin cabin |
Euro Medium: the modular cabinet
Euro Medium cabinets are assembled from panels, giving more than 224 sizes, from 500 x 500 x 300 to 1,250 x 2,000 x 500 mm. With no side reinforcements, they leave the whole surface free for wiring and are easy to drill on the sides. Numerous inserts in the back of the cabinet take equipment directly, and the hinges remain invisible from outside.
They are used for electrical distribution, instrumentation, water treatment, pumping, automation, traffic management, telephony, video and lighting.
Maxi Euro 1500: medium sized cabinets
Maxi Euro 1500 cabinets are 1,500 mm high and are assembled in modules from 750 to 1,250 mm wide, 430 or 630 mm deep. They are made entirely of glass reinforced polyester, with a gel coat finish, a textured anti poster polyurethane coating, an integrated rain canopy and IP65 and IK10 protection.
Two versions are available. The standard version (ST) is supplied as a kit and assembled on site, with no limit on the number of modules. The customised version (SP) is assembled at the factory, in one piece up to 6 or 7 modules, with built in options and mounting suited to very heavy loads.
Maxi Euro 1900: very large cabinets
Maxi Euro 1900 cabinets range from 1,800 x 600 x 430 mm to 1,900 x 5,325 x 1,000 mm. They use the same construction as the Maxi Euro 1500, as a standard version to assemble or as a customised version assembled at the factory for very heavy loads.
These dimensions suit electrical substations, solar installations, supervision equipment and rail or road infrastructure, when the installation exceeds the volume of a standard cabinet.
Euro Urbain: the street cabinet
Euro Urbain cabinets, from 920 x 720 x 250 to 1,500 x 2,000 x 800 mm, are designed for streets and roadsides. Their diamond point relief, on the door or the body, prevents fly posting, and their anti graffiti finish protects the surface. They are IP44 or IP55 and IK10, with a UV resistant gel coat.
Options include a police compartment, reinforcements for heavy loads, ventilation openings, forced ventilation or air conditioning, a canopy or a four sided pitched roof.
Mega Euro: GRP kiosks and shelters
Mega Euro cabins measure 2,400 x 2,300 mm, with a depth from 1,730 to 4,230 mm. They are moulded in two identical half shells bonded together, which allows the depth to be adjusted. Two finishes are available: single skin reinforced with beams embedded in the glass mat, or double skin with 20 to 40 mm of polyurethane foam.
Their thermal insulation coefficient, from 1 to 1.35 W/m².K according to the product sheet, limits heat and condensation inside. Doors can be placed on any side. For a custom cabin or shelter with its interior fit out, construction is handled by Gensollen, a group company.
Enclosures: Micro Euro, Mini Euro and Euro Instrum
For compact equipment, Europoly offers Micro Euro modular boxes, Mini Euro standard enclosures, from 300 x 250 x 160 to 1,000 x 800 x 340 mm in IP66 and IK10, and Euro Instrum instrumentation enclosures. They are detailed in our GRP enclosure guide.
Custom made
Custom made projects include emergency stop posts, water posts, battery enclosures, energy storage cabinets, FTTH cabinets and high voltage cabinets. The cabinet customisation page details the options, and double walled cabinets meet other needs.
Applications of GRP cabinets
Each application comes with its own equipment, site constraints and access conditions. Here is what each one covers, with related Europoly projects.
Telecoms and fibre optics
FTTH rollout, fibre to the home, requires street cabinets that house the operators’ connection and distribution equipment. Installed at the roadside, they are permanently exposed to the weather, impacts and vandalism. A polyester housing, which does not rust, limits maintenance over the life of the network.
Europoly fibre optic and telecom cabinets are customised to each operator’s requirements: cutouts and drilling in different positions, removable and modular products. This manufacturing approach allows large quantities to be produced at short notice.
Gas
A gas meter box contains the meter and a supply shut off system. It must remain permanently accessible to network technicians, according to TotalEnergies (in French).
From the service connection box to the cabinet or shelter housing a larger station, the housing protects these components from the weather and impacts while remaining accessible to operating teams. Our article on polyester gas enclosures and cabinets details the selection criteria.
Metering
A metering cabinet groups the meter, the cut out and the protective devices of a connection. In France, for a monitored power connection of 37 to 250 kVA, Enedis requires the main individual cut out to remain permanently accessible to the network operator. For public domain equipment, the Enedis note on additional metering requires a housing equivalent to IP 43 and IK 10.
Europoly cabinets include metering compartments that meet these access and protection needs. The article on outdoor polyester metering cabinets details these requirements.
Construction sites
On a construction site, boxes and cabinets distribute power to tools and machines. Single-phase (230 V) supplies portable power tools and three-phase (400 V) supplies powerful machines such as cranes or concrete mixers, according to 123elec (in French).
This equipment is moved, handled and exposed to impacts and rain. Europoly makes construction site boxes: socket boxes, fixed or mobile boxes and cabinets, modular distribution boxes. They start from standard enclosures or cabinets and are wired to the customer’s drawings, layout diagrams and specification. Wiring is the business of Polyelec, a group company.
Road safety
Along roads, motorways and in tunnels, emergency call posts allow road users to contact the emergency services. They must remain visible, withstand the weather, impacts and vandalism, and house communication equipment.
Europoly manufactures emergency call and stop posts in reinforced GRP, orange in colour, from the customer’s drawings or a standard model. Inserts embedded in the glass mat allow equipment to be fixed, and the post stands on a galvanised steel base.
Solar energy
A solar installation groups its protection, isolation and connection equipment outdoors, often in full sun. Industry specifications require corrosion resistance, anti graffiti protection, class II electrical insulation, an IP55 or IP44 protection rating and IK10 impact resistance.
Europoly solar cabinets meet these requirements, with a lightweight material that makes installation easier and better thermal insulation than an aluminium or metal cabinet. Our article explains how to choose a solar electrical cabinet.
Water: supply posts, sampling and treatment
On water networks, water supply posts and water sampling points house valves, fittings and plumbing. Their polyurethane foam insulation protects these parts from frost, and their colour can be chosen to blend into the site.
In wastewater treatment plants and treatment facilities, humidity and corrosive agents degrade metal housings. For a set of water analysis and treatment cabinets installed in the Paris sewers, Europoly used a resin and gel coat suited to these aggressive agents.
Urban areas
In towns, technical cabinets are exposed to fly posting, graffiti and impacts. The Euro Urbain range meets these constraints with a diamond point, anti poster and anti graffiti surface.
A guidance sheet from a French departmental architecture and heritage service also recommends integrating enclosures into the architecture: the same colour as neighbouring facades, grouped with other fittings.
Chemical and petrochemical industry
Environments laden with chemical agents require housings that resist corrosion over the long term, which gives glass reinforced polyester an advantage over metal solutions. On these sites, Euro Instrum enclosures protect the instrumentation: transmitters, manifolds and valves.
Industrial ports and marine environments
Salt spray greatly accelerates the deterioration of metal housings. Polyester cabinets limit this effect while reducing maintenance.
Rail and road infrastructure
Signalling, supervision, electrical distribution, metering or safety equipment: polyester enclosures and cabinets equip transport infrastructure.
For the Paris metro, Europoly designed a high voltage cabinet whose door system gives access to all internal components, from every side, without losing rigidity. For a tram network in Malaysia, the company designed a reinforced cabinet that houses a large track disconnector, with moulds and tooling made in house.
Electrical networks and street lighting
Polyester is valued for equipment that must remain available and withstand harsh weather. High voltage cabinets with several partitioned compartments make it possible to separate different power levels and equipment within the same housing.
Indoors
Indoors, polyester remains relevant when the environment is damp or corrosive: food processing plant, technical room, chemical site. The choice depends on the site environment, not on outdoor use alone.
For example, a drawer enclosure was made for testing dielectric equipment in a clean room laboratory, and a special machine cabinet was designed with an international manufacturer of cutting machines, then mass produced.
Other applications
Polyester can be moulded and shaped, which opens up many other applications. A few examples of projects:
- Access control: badge reader consoles, with a copper mesh laminated between two polyester skins to shield against electromagnetic interference.
- Energy storage: a two shelf battery enclosure for 22 batteries and 400 kg, with an acid retention tray and a roof access hatch.
- Mountains: remote avalanche triggering cabins, designed with the customer, for which Europoly made the tooling and carried out production.
- Measurement and analysis: protective canopies for analysers, junction boxes and measuring and control instruments.
- Data logging: a ventilated double walled cabinet, with an inner enclosure for the recorders and a removable base that can be buried.
Criteria for choosing a GRP cabinet
Environment and corrosion
IEC 60529 covers neither corrosion caused by saline or industrial atmospheres nor ageing under solar radiation. The site is described with the IEC 60721 series (part 3, section 4), and its corrosivity with ISO 9223 and ISO 12944 part 2, as Europoly details.
IP and IK ratings
The IP rating measures protection against dust and water, the IK rating resistance to impacts. The levels are detailed on the IP/IK protection rating page. A high IP rating does not cover internal condensation.
For most outdoor industrial installations, an IP65 polyester cabinet with an IK10 level is suitable. IK10 corresponds to resistance to a 20 joule impact.
Condensation and ventilation
Condensation occurs when the walls are colder than the dew point of the air inside. The balance between sealing and ventilation is covered in the article ventilated or sealed polyester cabinet.
Thermal management: do not confuse sealing and insulation
A perfectly sealed IP65 polyester cabinet is not necessarily suited to every thermal constraint.
When the installation is exposed to the sun or when the equipment inside gives off significant heat, the internal temperature can rise quickly.
Conversely, some configurations can encourage condensation as temperatures change between day and night.
To ensure equipment reliability, it may be necessary to include:
- filtered ventilation;
- specific louvres;
- heat exchangers;
- insulated sandwich construction.
Thermal management should be considered from the design stage to avoid costly corrective work after commissioning.
Ventilation, heat exchange, air conditioning and anti condensation heating solutions are detailed in our article on ventilating an outdoor electrical cabinet.
Dimensions, mounting and equipment
The usable dimensions must house the equipment, its wiring and maintenance access. To compare a cabinet and an enclosure, see the page GRP enclosures.
Finishes and colours
The finish determines long term durability, especially outdoors. Maxi Euro cabinets receive a gel coat and a textured anti poster polyurethane coating with high UV resistance, with a stated 10 year warranty on the coating. Euro Urbain cabinets have a UV resistant gel coat and an anti graffiti finish, Mega Euro cabins a gel coat outside and a top coat inside.
The manufacturing process matters too. Parts moulded in SMC, the process used for mass produced standard products, have no gel coat: they are more sensitive to UV than a part with gel coat, while remaining more resistant than sheet metal, as explained in Europoly manufacturing techniques.
The standard colour is light grey RAL 7035. Other colours are available on request, including a coloured coating to blend the cabinet into the site or follow a brand guideline, as shown on the custom made page. In public spaces, the colour is often set by the client.
Writing the specification
A precise specification avoids repeated exchanges. It can cover the following points:
- the application and the corrosivity class of the site;
- the usable dimensions, including equipment and access;
- the required IP and IK ratings;
- thermal management: ventilation, insulation, heating;
- the colour and appearance, set by the client;
- the mounting method: plinth, wall or pole;
- internal electrical wiring, which can be entrusted to Polyelec along with the cabinet;
- interior fit out, to be entrusted to Gensollen if needed.
How much does a GRP cabinet or enclosure cost?
The price of a polyester cabinet depends on many parameters:
- dimensions;
- IP rating;
- IK rating;
- built in equipment;
- level of customisation;
- regulatory constraints;
- installation environment.
Likewise, the cost of a polyester enclosure varies with its usable volume, its protection level and its configuration options.
Beyond the initial purchase cost, it is essential to assess the total cost of ownership. In aggressive environments, the durability of glass reinforced polyester often significantly reduces maintenance costs compared with some metal solutions.
From enclosure to complete project: Europoly, Gensollen and Polyelec
A polyester cabinet is often part of a larger project, with wiring, fit out and sometimes a shelter. The three companies of the group cover these steps. Our projects illustrate their work.
Europoly, the polyester housing
Europoly manufactures enclosures and cabinets in glass reinforced polyester, as well as standard cabins with the Mega Euro range.
Polyelec, wiring and electrical integration
Europoly manufactures the cabinet and, on request, Polyelec wires it: internal electrical wiring and electrical integration of the equipment.
Gensollen, cabins and fit out
Gensollen builds custom industrial cabins and shelters in insulated sandwich panels, and carries out their complete fit out: fixed and sliding furniture, HVAC ventilation, raised floors for cable routing.
Frequently asked questions
A polyester cabinet does not rust and does not conduct electricity. A metal cabinet has to rely on a paint system compliant with ISO 12944 and on stricter maintenance. The full comparison is in the article polyester cabinet or metal cabinet.
Europoly manufactures IP65 and IK10 polyester cabinets. Depending on the range, ratings go from IP44 to IP66 and up to IK10. Details are on the IP/IK protection rating page.
Good thermal management combines insulation, colour, siting, controlled ventilation, possibly heating, and a drainage plan. The article ventilated or sealed polyester cabinet details these choices.
A cabinet alone is never ATEX by nature: compliance depends on the overall design, the protection strategy and the certification of the assembly, as Europoly points out. Europoly cabinets meet the needs of ATEX zones, without claiming compliance.
From 300 x 250 x 160 mm enclosures to cabinets 1,900 mm high and 5,325 mm wide, and cabins of 2,400 x 2,300 mm, the ranges cover a wide spectrum. The usable dimensions must house the equipment, its wiring and maintenance access.
Europoly manufactures the polyester cabinet. On request, Polyelec, a group company, carries out the internal electrical wiring and electrical integration. Gensollen builds custom cabins and designs their fit out.
No. Glass reinforced polyester is naturally corrosion resistant and does not rust.
Service life depends on the installation environment, but it is generally longer than that of a painted steel cabinet used in the same aggressive conditions.
Yes. Outdoor polyester cabinets are particularly valued in marine environments for their excellent resistance to salt spray.
Yes. In most cases, a polyester cabinet can replace a metal housing, provided the dimensions, fixings, protection ratings and regulatory constraints of the site are checked.
Both protect against water jets, as shown by the second digit, 5. The difference is dust: an IP55 cabinet is dust protected, while an IP65 cabinet is completely dust tight.
In most outdoor industrial applications, IK10 is an excellent level of protection against mechanical impacts.
Do you have a GRP cabinet project?
The Europoly teams study your needs and the right range. Discover the full Europoly range or contact an advisor. On request, Polyelec handles wiring and electrical integration, and Gensollen builds cabins and fits them out.